Specifications:
| Model | LV-N12P | |
| Type | 2 output | |
| Output | PNP | |
| Cable/connector | Cable | |
| Main/Expansion unit | Expansion unit | |
| I/O | Control outputs | 2 output | 
| External input | 1 input | |
| Monitor output | None | |
| Output selection | LIGHT-ON/DARK-ON (switch-selectable) | |
| Timer function | Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, | |
| Control outputs | PNP open collector 30 V, Residual voltage 1.2 V or less (Output current: 10 mA or less) / 2.2 V or less (Output current: 10 to 100 mA) | |
| Response time | 80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1 | |
| Monitor output | - | |
| External input | Input time 2 ms (ON)/20 ms (OFF) or more*2 | |
| Number of interference | Connected to other than LV-S31: 0 for HIGH SPEED; 2 for FINE/TURBO/SUPER; 4 for ULTRA/MEGA,  | |
| Case size | H 32.6 mm × W 9.8 mm × L 78.7 mm | |
| Unit expansion | Up to 17 units can be connected in total (two-output type is treated as two units) | |
| Protection circuit | Reverse polarity protection, Over-current protection, Surge absorber | |
| Rating | Power voltage | 24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS | 
| Power | Normal: 950 mW or less (at 30 V. 33 mA at 24 V, 60 mA or less at 12 V)*4 | |
| Environmental resistance | Ambient temperature | -20 to +55 °C (No freezing)*6 | 
| Relative humidity | 35 to 85 % RH (No condensation) | |
| Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
| Shock resistance | 500 m/s2, 3 times in each of the X, Y, and Z directions | |
| Material | Cable | PVC | 
| Case | Main unit and cover material: Polycarbonate | |
| Weight | Approx. 65 g | |
 
                     
                                                                         
                     