RKC HBA-22 Heater break alarm module

2025-03-05 16:06:34 admin

RKC

HBA-22

Heater break alarm module

 

·       Input type: Current transformer (CTL-6-P-□, CTL-18S-□)

·       Detectable load current: 5A, 10A, 20A, 30A, 100A (depending on CT rating)

·       Settable range:

5A : 20 to 100% of rated value of CTL-6-P

10A, 20A, 30A : 50 to 100% of rated value of CTL-6-P

30A, 100A : 50 to 100% of rated value of CTL-18S

·       Alarm sensitivity: Alarm is activated hen the current changes by 15% or more of the rated value (full scale) of the CTL.
Changes below 15% may not activate the alarm.

·       Alarm output: 2 points, Relay contact, 1a contact

·       Supply voltage: 100/110V or 200/220V, (whichever is specified), 50/60Hz

·       Power consumption: 1.8VA or less

·       Ambient temperature: -10 to 50°C

 