KYOWA PCD-400B Sensor Interface
KYOWA
PCD-400B Sensor Interface
Specifications:
| Measuring Targets | Strain gage and strain-gage transducers | 
| Channels | 4 | 
| Input Form | Balanced differential input | 
| Synchronous Measurement | Up to 4 units by 16 channels | 
| Compatible Gage Resistance | Quarter bridge 2-wire system, 3-wire system: 120 Ω | 
| Input Connector | D-sub 37-pin connector | 
| Bridge Excitation | AC 2 Vrms | 
| Gage Factor | 2.00 fixed | 
| Balance Adjustment | Resistance: Within ±2% (±10 k ×10-6 strain)  | 
| Balance Adjustment Methods | Resistance: Auto balance | 
| Nonlinearity | Within ±0.1% FS | 
| Range | 200, 500, 1 k, 2 k, 5 k, 10 k, and 20 k ×10-6 strain – 7 steps | 
| Frequency Response | DC to 200 Hz, deviation: Within ±10% | 
| Sampling Frequencies | Max. 10 kHz (Synchronous 4-unit sampling for 16 channels at 10 kHz) | 
| LPF | Transfer characteristic: 2nd order Butterworth | 
| AD Converter | 24 bits | 
| Holding Setting Condition | The range and balance adjustment value etc. are written to nonvolatile memory. | 
| TEDS | Reads information from TEDS-installed sensors. | 
| Interfaces | USB2.0 (Conforms to High-speed USB standards.USB3.0 supported) | 
| Stability | Temperature | 
| Withstand Voltage | 250 VAC for 1 minute between input and case | 
| Operating Temperature | 0 to 40ºC | 
| Operating Humidity | 20 to 85% (Non-condensing) | 
| Vibration Resistance | ±29.42 m/s2 (3 G) | 
| Power Supply | 11 to 16 VDC | 
| Current Consumption | 0.7 A or less (12 VDC) | 
| Dimensions | 210 W x 35 H x 157.5 D mm (Excluding protrusions) | 
| Weight | Approx. 650 g | 
| Compliance | Directive 2011/65/EU, (EU)2015/863 (10 restricted substances) (RoHS) Directive 2014/30/EU (EMC) | 
| Degree of Protection | IP30 (JIS C 0920 / IEC 60529) | 
| *The specifications apply to the state in which the temperature has stabilized after a preheating time of 1 hour. | 
 
                     
                                                                         
                     