HIOKI SWITCH MAINFRAME SW1001
HIOKI
SWITCH MAINFRAME
SW1001
Packed with Features to Assure Accuracy in Multi-channel Battery Testing
Basic specifications
Slots | 3 slots |
Supported modules | MULTIPLEXER MODULE SW9001 (2-wire/4-wire) |
Connectible instruments | Max. 2 units |
Max. input voltage | 60 V DC (Cannot connect to battery packs in excess of 60 V DC), 30 V AC rms, 42.4 V peak, Maximum rated voltage to ground: 60 V DC |
Communication I/F | LAN, USB, RS-232C (for host, for measurement instruments) |
Functions | Channel switching, wiring method, scan function, communication command transmission, channel delay, shield switching |
Power supply | 100 to 240 V AC / 30 VA (50/60 Hz) |
Dimensions and mass | 215 mm (8.46 in) W × 132 mm (5.20 in) H × 420 mm (16.54 in) D, 3.7 kg (130.5 oz) |
Included accessories | Power cord ×1, instruction manual ×1, usage precautions ×1, USB driver CD ×1 |
Basic specifications for MULTIPLEXER MODULE
SW9001 | SW9002 | |
Wiring method | 2-wire or 4-wire | 4-terminal pair (6-wire) or 2-wire |
No. of channels | 22 channels (2-wire) / 11 channels (4-wire) | 6 channels (4-terminal pair) / 6 channels (2-wire) |
Contact method | Armature relays | |
Channel switching time | 11 ms (excluding measurement time) | |
Max. allowable voltage | 60 V DC, 30 V AC rms, 42.4 V peak | |
Max. allowable current | 1 A DC, 1 A AC rms | 1 A DC, 1 A AC rms (Sense), 2 A DC, 2 A AC rms (Source, Return) |
Max. allowable power | 30 W (resistive load) | |
Maximum rated voltage to ground | 60 V DC | |
Dimensions and mass | 25.5 mm (1.00 in) W × 110 mm (4.33 in) H × 257 mm (10.12 in) D, 210 g (7.4 oz) | 25.5 mm (1.00 in) W × 110 mm (4.33 in) H × 257 mm (10.12 in) D, 196 g (6.9 oz) |
Included accessories | Instruction manual ×1 |