AND ​LC-4001A / LC-4001 Loadcells

2024-07-19 16:42:13 admin

AND

LC-4001A / LC-4001 

Loadcells

 

Model No.

Capacity

LC4001A-G120

120 gf

LC4001-G120

120 gf

 

Specifications:

 

Rated capacity (R.C.) ......................................1.2N (122.4 gf) 
Rated output (R.O.) ......................................0.4079 mV/ V or greater
Safe load limit ......................................300% of R.C.
Combined error.................................. ±0.015% of R.O.
Zero balance....................................... 40±25% of R.O. 
Temperature compensation range .............................-5 °C to +35 °C/+23 °F to + 95°F 
Recommended excitation voltage ................................5V to 12 V DC 
Maximum excitation voltage ................................15 V DC
Input terminal resistance ..................Approximately 400 Ω 
Output terminal resistance ...............350 Ω ± 5 Ω 
Insulation resistance .........................Greater than 5000 MΩ at 50 V DC
Temperatureeffect on:
Zero ......................................................0.14% of R.O./10°C 
Span .....................................................0.02% of Load/10°C Typ. 
Platform size ......................................120 × 120 mm /4.7 × 4.7 inches 
Cable length .......................................Φ4/1.5m (LC4001A) / F.P.C 74 mm (LC4001)

 