Rated capacity (R.C.)
| X-500 kg Y-250 kg (X:5 kN, Y:2.5 kN) X-750 kg Y-250 kg (X:7.5 kN, Y:2.5 kN) X-1000 kg Y-500 kg (X:10 kN, Y:5 kN) |
Rated output (R.O.) | 2 mV/V ±1% (for X, Y) |
Non linearity | 0.1% R.O. |
Hysteresis | 0.05% R.O. |
Repeatability | 0.05% R.O. |
Recommended excitation voltage | 5 V to 10 V AC/DC |
Max. excitation voltage | 20 V AC/DC |
Zero balance | ± 1% R.O. |
Input terminals bridge resistance | 350 Ω ± 3.5 Ω |
Output terminals bridge resistance | 350 Ω ± 3.5 Ω |
Insulation resistance | 2000 MΩ (B/E DC 50 V) |
Cable diameter/length | φ7, 4-core shielded cable, 10 m, connector end |
Zero point temperature effect | 0.05% R.O./10 °C |
Temperature effect on output | 0.05% Load/10 °C |
Temperature compensated range | –10 °C to +70 °C |
Temperature usable range | –10 °C to +70 °C |
Safe overload | 150% R.L. |
Limited overload | 200% R.L. |
Dustproof/Waterproof | IP54 |
Natural frequency | More than 1 kHz |
Crosstalk | 2.5 N or less (5 kN / 2.5 kN) 5.0 N or less (7.5 kN /5 kN, 10 kN, / 2.5 kN, 5 kN / 5 kN) |