| Rated capacity (R.C.)
 | X-500 kg Y-250 kg (X:5 kN, Y:2.5 kN)X-750 kg Y-250 kg (X:7.5 kN, Y:2.5 kN)
 X-1000 kg Y-500 kg (X:10 kN, Y:5 kN)
 | 
| Rated output (R.O.) | 2 mV/V ±1% (for X, Y) | 
| Non linearity | 0.1% R.O. | 
| Hysteresis | 0.05% R.O. | 
| Repeatability | 0.05% R.O. | 
| Recommended excitation voltage | 5 V to 10 V AC/DC | 
| Max. excitation voltage | 20 V AC/DC | 
| Zero balance | ± 1% R.O. | 
| Input terminals bridge resistance | 350 Ω ± 3.5 Ω | 
| Output terminals bridge resistance | 350 Ω ± 3.5 Ω | 
| Insulation resistance | 2000 MΩ (B/E DC 50 V) | 
| Cable diameter/length | φ7, 4-core shielded cable, 10 m, connector end | 
| Zero point temperature effect | 0.05% R.O./10 °C | 
| Temperature effect on output | 0.05% Load/10 °C | 
| Temperature compensated range | –10 °C to +70 °C | 
| Temperature usable range | –10 °C to +70 °C | 
| Safe overload | 150% R.L. | 
| Limited overload | 200% R.L. | 
| Dustproof/Waterproof | IP54 | 
| Natural frequency | More than 1 kHz | 
| Crosstalk | 2.5 N or less (5 kN / 2.5 kN)5.0 N or less (7.5 kN /5 kN, 10 kN, / 2.5 kN, 5 kN / 5 kN)
 |