AND LC4212-K300 LC4212-K600 LC4212-T1.2 Load cell
AND
LC4212-K300 LC4212-K600 LC4212-T1.2
Load cell
| Capacity | Model No. | 
| 300 kgf | LC4212-K300 | 
| 600 kgf | LC4212-K600 | 
| 1.2 tf | LC4212-T1.2 | 
Specifications:
| Rated capacities .......................... | 300 kgf, 600 kgf, 1.2 tf | 
| Rated output .................................. | 1.5 mV/V+15%/-0%(1 mV/V+15%/-0%)* | 
| Maximum deadweight ................. | 20% (50%) of rated capacity | 
| Maximum safe overload .............. | 200% of rated capacity | 
| Combined error ............................ | ±0.015% of rated output | 
| Creep .............................................. | ±0.05% of rated output/hour | 
| Zero balance ................................. | 25±10% of rated output | 
| Compensated | |
| temperature range ........................ | -10 °C to +40 °C/+14 °F to +104 °F | 
| Recommended | |
| excitation voltage ........................... | 12 V | 
| Maximum | |
| excitation voltage ........................... | 15 V | 
| Input terminal resistance .............. | Approximately 200 Ω | 
| Output terminal resistance ......... | 175 Ω ± 1 Ω | 
| Insulation resistance ................... | Greater then 500 MΩ at DC50 V | 
| Temperature effect | |
| Zero ................................................. | 0.004% of rated output/°C | 
| Span ................................................ | 0.0014% of rated output/°C Typ. | 
| Platform size .................................. | 0.9 × MAX. 2.0 m (35 × MAX. 79 inches) | 
| Weight ............................................ | 50 kg (30 kg) 110 Ibs (66 lbs) | 
| Cable length ................................. | 2 m/79 inches | 
 
                     
                                                                         
                     