OMRON E5CC-CQ0ASM-000 E5CC-CQ0DSM-000 E5CC-CQ2ASM-000 E5CC-CQ2ASM-001 E5CC-CQ2ASM-002 E5CC-CQ2ASM-003 E5CC-CQ2ASM-004 E5CC-CQ2ASM-005 E5CC-CQ2ASM-006 E5CC-CQ2ASM-007 E5C
OMRON
E5CC-CQ0ASM-000 E5CC-CQ0DSM-000 E5CC-CQ2ASM-000 E5CC-CQ2ASM-001 E5CC-CQ2ASM-002 E5CC-CQ2ASM-003 E5CC-CQ2ASM-004 E5CC-CQ2ASM-005 E5CC-CQ2ASM-006 E5CC-CQ2ASM-007 E5CC-CQ2DSM-000 E5CC-CQ2DSM-001 E5CC-CQ2DSM-002 E5CC-CQ2DSM-003 E5CC-CQ2DSM-004 E5CC-CQ2DSM-005 E5CC-CQ2DSM-006 E5CC-CQ2DSM-007 E5CC-CQ3ASM-000 E5CC-CQ3ASM-001 until E5CC-RX3DSM-006 E5CC-RX3DSM-007
Digital Temperature Controller (48 x 48 mm)
Specifications:
Consult with us when ordering any models that are not listed .
Power supply voltage | A in model number: 100 to 240 VAC, 50/60 Hz | |
Operating voltage range | 85% to 110% of rated supply voltage | |
Power consumption | Models with option selection of 000:5.2 VA max. at 100 to 240 VAC, and 3.1 VA max. at | |
Sensor input | Temperature input | |
Input impedance | Current input: 150 Ω max., Voltage input: 1 MΩ min. | |
Control method | ON/OFF control or 2-PID control (with auto-tuning) | |
Control | Relay output | E5CC/E5CC-B: |
Voltage output | Output voltage: 12 VDC ± 20% (PNP), max. load current: 21 mA, with short-circuit | |
Linear current | 4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000 | |
Auxiliary | Number of | E5CC: 3 |
Output | SPST-NO relay outputs, 250 VAC, Models with 1 output: 3 A (resistive load), E5CC-U | |
Event | Number of inputs | E5CC: 2 or 4 (depends on model) |
External contact | Contact input: ON: 1 kΩ max., OFF: 100 kΩ min. | |
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max. | ||
Current flow: Approx. 7 mA per contact | ||
Transfer | Number of | 1 (only on models with a transfer output) |
Output | Current output: 4 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000 | |
Setting method | Digital setting using front panel keys | |
Remote SP input *1 *2 | Current input: 4 to 20 mA DC or 0 to 20 mA DC (input impedance: 150 Ω max.) | |
Indication method | 11-segment digital display and individual indicators | |
Multi SP *3 | Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key | |
Bank switching | None | |
Other functions | Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm | |
Ambient operating | -10 to 55°C (with no condensation or icing), For 3-year warranty: -10 to 50°C with | |
Ambient operating humidity | 25% to 85% | |
Storage temperature | -25 to 65°C (with no condensation or icing) | |
Altitude | 2,000 m max. | |
Recommended fuse | T2A, 250 VAC, time-lag, low-breaking capacity | |
Installation environment | Overvoltage category II, Pollution Degree 2 (EN/IEC/UL 61010-1) |