KEYENCE LR-ZH500N Rectangular w/ cable type, 500 mm
KEYENCE
LR-ZH500N
Rectangular w/ cable type, 500 mm
Specifications:
Model | LR-ZH500N | |
Type | U.C.D. Function | |
Shape | Rectangular | |
Output | NPN | |
Cable connection | 2 m cable | |
Detectable distance | 35 to 500 mm (465 to 0)*1 | |
Standard detectable deviation | 35 to 180 mm: 9 mm | |
Display resolution | 1 to 5 (1 to 5 mm) | |
Spot diameter | Approx. ø3 mm | |
Response time | 1.5 ms / 10 ms / 50 ms selectable | |
Light source | Type | Red laser (660 nm) |
Laser class | Class 2 laser product (IEC60825-1) | |
Function | Indicator | 3-digit 7-segment display (white), |
Timer | OFF/ON delay/OFF delay/One-shot | |
Rating | Power voltage | 10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS |
Power consumption | 450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V) | |
Specifications | Control output | NPN Open collector, |
Protection circuit | Protection against reverse power connection, output overcurrent, output surge, reverse output connection | |
Output operation | Light-ON / Dark-ON selectable | |
External input | Input time calibration: 35 ms or more ON, 35 ms or more OFF | |
Environmental resistance | Enclosure rating | IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*2, Diversey*2 |
Insulation resistance | 20 MΩ or more (500 VDC) | |
Ambient light | Incandescent lamp: 10,000 lux or less | |
Ambient temperature | -10 to +50 °C (No freezing) | |
Storage temperature | -25 to +75 °C (No freezing) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Withstand voltage | 1,000 VAC, 50/60 Hz, 1 min | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 1,000 m/s2, 6 times in each of the X, Y, and Z directions | |
Material | Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating, | |
Accessories | Instruction Manual, | |
Weight | Approx. 110 g (Including cable) | |
*1 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed. |