KEYENCE PS-N10 Amplifier Unit, Zero-line Expansion Unit

2024-10-04 15:31:50 admin

KEYENCE 

PS-N10

Amplifier Unit, Zero-line Expansion Unit

 

Specifications:

Model

PS-N10

Type

Zero line

Output

-

Main unit/Expansion unit

Expansion unit

I/O

Control outputs

None*1

External input

None

Output selection

LIGHT-ON/DARK-ON (switch-selectable)

Timer function

Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9999 ms, Maximum error against the setting value: ±10% max.

Control output

Number of interference prevention units

4 for TURBO/SUPER/ULTRA/MEGA (When set to DOUBLE, the number of interference-prevention units will be doubled)

Response time

500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)

External input

Input time 2 ms (ON)/20 ms (OFF) or more*2

Case size

H 32.6 mm × W 9.8 mm × L 78.7 mm

Unit expansion

Up to 16 units (Up to 17 units including 1 main unit can be connected in total.)

Protection circuit

Reverse polarity protection, Over-current protection, Surge absorber

Rating

Power voltage

24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS

Power consumption

Normal: 810 mW or less (at 30V. 28 mA max. at 24 V, 34 mA max. at 12 V)
Eco on mode: 700 mW or less (at 30V. 24 mA max. at 24 V, 27 mA max. at 12 V) Eco Full mode: 490 mW or less (at 30V. 17 mA max. at 24 V, 20 mA max. at 12 V)

Environmental resistance

Ambient temperature

-20 to +55 °C (No freezing)*3

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Material

Case

Main unit and cover material: Polycarbonate

Cable

PVC