ZHIXIN ZX1376 series DC bias current source and bridge bias all-in-one machine
ZHIXIN
ZX1376 series
DC bias current source and bridge bias all-in-one machine
Technical parameters | |||
Model | ZX1376 | ZX1376X | |
Show | 4.3" LCD | 4.3" LCD | |
Operation | Physical button + foot control switch | Physical button + foot control switch | |
Support measurement frequency | 0Hz-2MHz | ||
Current range | 0-25A | 0-25A | |
Current | Measure range | 0mA-1.000A, 1.000A-5.000A, 5.0A-25A | |
Step by step | 0.25mA, 1.25mA, 6.25mA | ||
Scanning adjustment time | 4ms-3600s | 10ms-3600s | |
Maximum output voltage | 11V (11V voltage can be output under all current conditions!!!) | ||
Maximum allowable DC resistance | Rmax=Vmax/I (Ω) (Please refer to the user manual for the calculation of Rmax) | ||
Maximum allowable inductance | Lmax=Vmax/(di/dt) (mH) (Please refer to the user manual for the calculation of Lmax) | ||
Measurement method | Automatic | ||
Start and stop control mode | START/STOP physical buttons, 4 kinds of foot control, bus | ||
Maximum current time for continuous loading | Conservative 2-3h, uninterrupted output | ||
Function | Instrument fault self-test; 99 sets of custom file management; dual progress bar instructions; Chinese and English bilingual; slave soft switch; real-time operation; SCPI instruction set; simple dual-display calculator, etc. | ||
Interface | SlaverLink, RS232C, UsbHost, USB Device, Handler, GPIB (optional) | ||
Power supply requirements | Voltage: 100~120 Vac or 198~242 Vac | ||
Frequency: 46-64 Hz, power greater than 50 VA | |||
Temperature and humidity | 0℃~40℃, relative humidity ≤75% | ||
Volume (WxHxD) | 430mmx178mmx465mm | ||
Weight (net weight) | 19Kg |
Technical parameters | ||
Model | Function parameters of ZX1376X bridge | |
Test frequency | 50Hz~200kHz, More than 12,000 frequency points | |
Test parameters | C, L, X, B, R, G, D, Q, ESR, Rp, θ, |Z|,|Y|,P | |
Test level | 10mV-2Vrms | |
Basic accuracy | 0.05% accuracy table shall prevail | |
Test speed | Fast: 50 times per second, medium speed 20 times per second, slow speed 6 times per second (Frequency above 1kHz) | |
Show show Fan Encirclement | |Z|, R, X | 0.01 mΩ ~ 99.9999MΩ |
|Y|, G, B | 0.00001μS~99.9999S | |
C | 0.00001pF~9.99999F | |
D | 0.00001~9.99999 | |
DCR | 0.01mΩ~99.9999MΩ | |
L | 0.00001μH~99999.9H | |
Q | 0.01~99999.9 | |
θ(RAD) | -3.14159~3.14159 | |
θ(DEG) | -179.999 °~179.999° | |
Δ% | -99.999%~99.999% | |
Signal source output resistance | 30Ω, 100Ω, 10/CC | |
Measurement method | Automatic, maintain | |
Trigger mode | Internal, manual, automatic, external, bus | |
Calibration function | Open/short circuit, full frequency zero, point frequency zero | |
Equivalent circuit | Series, parallel connection | |
Comparator | Three-level sorting, BIN0~BIN2 | |
PASS, HI, LOW (PASS/FAIL LED displ |