OMRON ​ZJ-SDA11 ZJ-SD100 Fan Ionizer

2024-07-17 16:17:12 admin

OMRON

ZJ-SDA11 ZJ-SD100 

Fan Ionizer

 

Specifications:

 

Sensor Head

Model

ZJ-SD100

Applicable Amplifier

ZJ-SDA11

Sensing distance

5 to 100 mm

Measurement voltage

Standard mode: ±50 KV, Precision mode: ±5 KV max. *1

Display resolution

Standard mode: 10 V, Precision mode: 1 V *2

Linearity *3

±5% FS *4

Response time

20 ms

Ambient temperature range

Operating and storage: 0 to 50°C (with no condensation or icing)

Ambient humidity range

Operating and storage: 35% to 85% (with no condensation)

Dielectric strength

1,000 VAC, 50/60 Hz, 1 min *5

Vibration resistance

Sensor Head: 3-mm double amplitude at 10 to 55 Hz for 45 min each in the X, Y, and Z 
directions, 
Preamplifier: 1.5-mm double amplitude at 10 to 55 Hz for 2 h each in the X, Y, and Z 
directions

Degree of protection

IP20

Connecting method

Pre-wired Connector (standard length: 2 m)

Weight (packed state)

Approx. 150 g

Materials

Sensor Head: Stainless steel 
Preamplifier: PC

Accessories

Instruction sheet, Preamplifier Mounting Brackets (ZX-XBT1)

*1. The measurement may become saturated if the Sensor is too close to an object being measured, even if it is within 
       the measurement voltage range. Use the distance from the measurement surface (mm) times 1 KV as a guide. 
*2. This is the minimum value obtainable when a ZJ-SDA11 Amplifier Unit is connected. 
*3. When the ambient temperature is stable at 25°C. 
*4. When the measurement distance is 10 mm and the measurement voltage is -5 to 5 KV. 
*5. When a Preamplifier is used (excluding the Sensor Head).

Amplifier

Model

ZJ-SDA11

Measurement period

1 ms

Possible average count 
settings *1

1, 2, 4, 8, 16, 32, 64, 128, 256, 512, or 1,024

Linear output *2

Current output: 4 to 20 mA/FS, Max. load resistance: 300 Ω 
Voltage output: ±4 V (±5 V, 1 to 5 V *3), Output impedance: 100 Ω

Judgment outputs 
(3 outputs: OPE1, OPE2, 
and OPE3)

NPN open-collector output, 30 VDC, 20 mA max. 
Residual voltage: 1.2 V max.

Bank shift input, zero reset 
input, timing input, reset 
input

ON: Short-circuited with 0-V terminal or 1.5 V or less 
OFF: Open (leakage current: 0.1 mA max.)

Functions

Measurement value display, display reverse, scaling, peak and bottom hold, distance 
compensation, present value display, limit number of display digits, monitor focus, 
mask hold, sensing area compensation, output value display, zero reset, linear output 
compensation, distance trigger, warning output, setting value display, zero reset 
memory, peak hold, delay hold, bank switching, resolution display, various timers, 
bottom hold, delay time setting, enable display, initialization, sample hold, timing inputs, 
zero reset display, teaching, peak-to-peak, key lock, judgment output display, direct 
threshold value setting, hold, clamp value setting, ECO mode, hysteresis adjustment, 
average hold, precise measurement mode

Indications

Operation indicators (OPE1 (orange), OPE2 (green), OPE3 (yellow), 7-segment main 
digital display (red), 7-segment sub-digital display (yellow), power ON indicator (green), 
zero reset indicator (green), enable indicator (green)

Power supply voltage

24 VDC ±10%, Ripple (p-p): 10% max.

Current consumption

24-VDC power supply: 140 mA max.

Ambient temperature range

Operating and storage: 0 to 50°C (with no icing or condensation)

Ambient humidity range

Operating and storage: 35% to 85% (with no condensation)

Insulation resistance

20 MΩ (at 500 VDC)

Dielectric strength

1,000 VAC, 50/60 Hz, 1 min

Shock resistance

Destruction: 300 m/s2 3 times each in 6 directions (up/down, left/right, and forward/ 
backward)

Vibration resistance

Destruction: 0.7-mm double amplitude at 10 to 150 Hz for 80 min each in the X, Y, and 
Z directions

Connecting method

Pre-wired (standard length: 2 m)

Weight (packed state)

Approx. 350 g

Materials

Case: PBT (polybutylene terephthalate), Cover: Polycarbonate

Accessories

Instruction sheet

 


首页