Specifications:

Model

KS1-AA1T

Power supply voltage

24 VDC ±5%

Current consumption

Approx. 100 mA

Discharge method

High-frequency AC (Approx. 68 kHz)

Output voltage

±2 kV

Safety circuit

Outputs alarms for ionization errors

Discharge time

0.8 s max. (at a distance of 50 mm from air outlet)

Ion balance

±15 V or less (at a distance of 50 mm from air outlet)

Fluid used

Air (refer to Air Used on Catalog)

Amount of

0.04 ppm or less (when standard nozzle used, at a distance of 300 mm from air outlet and 
primary side voltage of

generated ozone

0.25 MPa)

Supplied air flow

Approx. 100 L/min (ANR) (when standard nozzle used, at primary side voltage of 0.15 Mpa)

Indicators

Green POWER indicator lit while Ionizer ON, red ALM indicator lit for ionizing errors.

Air pressure range

When Standard Nozzle or Flexible Tube Nozzle is used.

0.02 to 0.25 MPa

When Standard Nozzle Tube is attached.

0.02 to 0.12 MPa

When Shower Nozzle, Flat Nozzle, or Straight Bar Nozzle is used.

0.05 to 0.40 MPa

Operating ambient 
temperature

0 to 40°C (with no icing or condensation)

Operating ambient 
humidity

35% to 65% (with no condensation)

Weight

235 g (Ionizer only)

Accessories

One ground lead (2 m)

 

 