OMRON ​XW2R (PLCs) Connector-Terminal Block Conversion Units for PLCs

2024-08-08 16:07:00 admin

OMRON

XW2R (PLCs)

 Connector-Terminal Block Conversion Units for PLCs

 

Specifications:

Models for Connection to OMRON PLCs

with power supply terminals

e-CON Type

Rated current

Power supply terminal block: 4 A/16 poles or 8 A/32 poles

Connectors/e-CON Connectors: 1 A 
(However, rated current of e-CON Connector depends on the wires that are used.)

Rated voltage

24 VDC

Insuration resistance

100 MΩ min. (at 500 VDC)

Dielectric strength

500 VAC for 1 min (leakage current: 1 mA max.)

Ambient operating temperature

0 to 55°C

Applicable
wires

Applicable wire sizes

AWG 24 to 14 (ferrules) 
AWG 28 to 14 (stranded wires) 
AWG 28 to 16 (solid wires) * 
(Outer diameter of insulation must be 4 mm max)

Stripped length

AWG 28-16: 8 to 10 mm 
AWG 14: 9 to 10 mm

* This is the applicable range for the power supply terminal block. For the applicable wire sizes for I/O Connectors (e- 
   CON), refer to "Input Device Connectors: XN2 e-CON Connectors".

without power supply terminals

Phillips screw

Rated current

0.5 A/signal, 4 A/common

Rated voltage

24 VDC

Insuration resistance

100 MΩ min. (at 500 VDC)

Dielectric strength

500 VAC for 1 min (leakage current: 1 mA max.)

Ambient operating temperature

0 to 55°C

Applicable wires

Applicable wire sizes

AWG 22 to 16 (round or forked crimp terminals) 
AWG 26 to 16 (stranded or solid wires)

Stripped length

9 mm

Tightening

0.5 Nm

Slotted screw (rise up)

Rated current

0.5 A/signal, 4 A/common

Rated voltage

24 VDC

Insuration resistance

100 MΩ min. (at 500 VDC)

Dielectric strength

500 VAC for 1 min (leakage current: 1 mA max.)

Ambient operating temperature

0 to 55°C

Applicable wires

Applicable wire sizes

AWG 22 to 16 (ferrules) 
AWG 26 to 16 (stranded or solid wires)

Stripped length

7 mm

Tightening

0.5 to 0.6 Nm

 